Purlins are easy to overlook on a drawing, but on most industrial sheds and pre-engineered buildings (PEBs) they are one of the largest secondary-steel items in the bill of quantities. The first choice the designer makes is the profile: a C purlin or a Z purlin. Both are cold-formed from steel strip, both carry roof sheeting to the main frames, and both are widely available in Jaipur and across Rajasthan. They do, however, behave differently over multiple bays, and that difference shows up in tonnage, erection and cost.
This guide explains how each profile works, where each one fits, and what to send your supplier so the quotation matches the design.
What purlins and girts do
A purlin is the horizontal member that spans between rafters and supports the roof sheets. A girt does the same job on the walls, carrying the wall cladding between columns. In a typical PEB or industrial shed, both are made from cold-formed light gauge steel: strip that is roll-formed at room temperature into a C or Z shape, usually with stiffening lips on the flanges.
In India, the dimensions, mass and sectional properties of cold-formed light gauge sections are covered by IS 811:1987, and the design of cold-formed members is covered by the code of practice IS 801:1975. IS 811 gives section geometry; the strength check itself is done to IS 801 (or to the design basis your PEB engineer has adopted).
C purlins: simple, symmetrical and easy to handle
A C purlin (also called a C section or lipped channel) has a web and two equal flanges, each with a return lip. Because the flanges are the same size, two C sections cannot be nested inside one another to form a lap.
Where C purlins work well:
- Single-span purlins: each purlin runs from one rafter to the next and is bolted at each end.
- Edges and openings: eave struts, framing around skylights, roof openings, louvers and doors.
- Short or single-bay buildings, where there is little continuity to gain.
- Mezzanine and light framing, canopies and smaller structures where a simple, symmetrical section is easier to detail.
C sections are straightforward to cut, punch and erect, which is why they remain common on smaller sheds and for secondary framing around openings.
Z purlins: built to lap over supports
A Z purlin has its two flanges pointing in opposite directions. Manufacturers usually make the two flanges slightly different in width, so that one Z section can nest over another at a support. This lapped joint lets a line of Z purlins act as a continuous member along the length of the building rather than a series of separate single spans.
Continuity matters because the bending moment in a continuous purlin is shared between mid-span and the supports, and the lap places two thicknesses of steel exactly where the moment over the support is greatest. On long, multi-bay buildings this usually allows a lighter section or a longer bay spacing than the same purlin used as simple spans, and it reduces deflection.
Where Z purlins work well:
- Long warehouses, factory sheds and PEBs with many equal bays.
- Buildings where purlin tonnage is a meaningful share of the steel cost.
- Roofs with a consistent bay spacing, where lap lengths can be repeated.
C vs Z purlin: side-by-side
| Factor | C purlin | Z purlin |
|---|---|---|
| Shape | Symmetrical, equal flanges | Flanges on opposite sides, usually slightly unequal |
| Can be lapped (nested) at supports | No | Yes |
| Typical span arrangement | Single span, or continuous with sleeves | Lapped continuous over multiple bays |
| Best suited to | Small sheds, openings, eave struts, light framing | Long multi-bay roofs and walls |
| Steel efficiency over many bays | Lower | Usually higher, because of continuity |
| Handling and detailing | Simpler | Needs lap lengths and bolt patterns set out in the design |
So which one should you use?
Neither profile is better in every case. The structural design should decide, based on the span (bay spacing), purlin spacing, roof and wind loads, sheeting type and the number of bays. As a practical rule of thumb:
- If the building has many repeated bays, a lapped Z purlin system is usually worth evaluating first.
- If the building is short, irregular, or the members frame openings, C sections are usually simpler.
- Many PEBs use both: Z purlins in the main roof field, and C sections for eave struts, openings and framing details.
Do not change a designed Z system to C sections (or the other way round) on site to suit availability without the designer’s approval. The two are not interchangeable member-for-member.
Galvanised or plain (black) purlins?
Purlins are supplied either from pre-galvanised (GI) strip or from uncoated hot-rolled strip that is painted after fabrication. Galvanised purlins are widely used for roofs and walls because the zinc coating protects the steel without site painting. The coating mass you need depends on the environment: an inland dry location and a coastal or chemical-exposure site are not the same. Specify the coating along with the section so that quotations can be compared like for like.
What to include in a purlin enquiry
A complete enquiry gets a faster and more accurate quotation. Include:
- Profile and size: C or Z, depth, flange width, lip and thickness (for example, the section designation from your drawing).
- Material and coating: GI or plain, and any coating mass or grade specified.
- Lengths and quantities: a cutting list or purlin schedule, including lap lengths for Z systems.
- Hole punching: connection drawing or hole pattern, if purlins are to be punched to suit cleats.
- Site location and required delivery date.
ISERN Industries supplies C and Z purlins and cold-formed sections from Bagru, Jaipur, with cutting to length and punching to suit your connection drawings. See C & Z purlins and cold-formed sections, or browse related roofing and cladding sheets and standing seam roofing.
Frequently asked questions
Is a Z purlin stronger than a C purlin?
Not as an individual member of the same size and thickness. The advantage of a Z purlin comes from lapping at supports, which makes the line continuous and puts double thickness where the support moment is highest. Over several bays, that often allows a lighter section.
Can C purlins be made continuous?
C sections cannot be nested, so they are not lapped like Z sections. They are normally used as single spans, although some systems make them continuous with sleeves at the supports. Your designer will specify the arrangement.
Which Indian Standard covers cold-formed purlin sections?
IS 811:1987 covers the dimensions and sectional properties of cold-formed light gauge structural steel sections, and IS 801:1975 is the code of practice for designing cold-formed light gauge members in building construction.
Do you deliver purlins outside Jaipur?
Yes. ISERN supplies across Rajasthan and to other states. Include the site location in your enquiry.
Have a purlin schedule or BOQ? Send it to ISERN for a quotation, call +91 97733 52377 or email [email protected].